Receivers: Barrel/Endcap summing


Some cables are required between Barrel and Endcap receivers for summing across the transition. The lengths will be either 1m (in the same rack) or about 5m (via underfloor cable tray between racks). If the summing is from Barrel to Endcap this may be within the latency difference between them.



Mergers to CTP


Route is down through the floor. Approximate length 5m down and 12*0.7m across, say 14m for furthest merger, maybe 12.5m for nearest merger. (CTP and TTC are now quite off centre).



Glinks to RODs


If RODs are placed centrally, cable lengths will be under 3m. If the RODs are at the edge, this rises to about 12m.



Likely minimum and maximum cable lengths


Path: Min Max Safe? TDR
RX to PPM: 4.2m 8.9m 5m 10m
PPM to CPM/JEM: 7.8m 9.0m 8m 10/7.5m
Between CP Mergers: 1.7m 4.2m 2m 2.5m
Between JEP Mergers: 1.0m 1.0m 1m 2.5m
Mergers to CTP: 12.5m 14.0m 13m 2m?
CTP to TTC : 5m 5m 5m 8m?
Total cable: 30.5m 41.1m 32m 30m?
Total RX-CMM: 13.7m 22.1m 14m 20m?
Cable latency/ticks: 6 8 6.5 6?


next up previous
Next: Outstanding Issues Up: l1joint_1102_racks Previous: Cable lengths: CP and
Murrough Landon (m.p.j.landon@qmw.ac.uk)