LAr Cables
Cables | Pairs | Crates | TxB*Cables | |
Barrel | 128 | 16 | 32 | 2 * 2 |
EMEC | 112 | 16 | 8*2.5 | (2,3,2) * 2 |
HEC | 96 | 16 | 8*0.5 | 2 * 6 |
FCAL | 24 | 16 | 0.5 | 2 * 6 |
Total | 360 |
TileCal Cables
Cables | Pairs | Comments | |
Barrel | 128 | 9 | One/drawer/end |
Ext Barr | 128 | 6? | One/drawer/end |
Total | 256 |
NB The Muon trigger also has 256 TileCal cables.
Holes in Shielding Wall
LAr cable diameter is 12.7mm. Using 15mm for safety, 360 cables
occupy 81,000mm. Connector is 20*70=1400mm
.
Suppose (worst case) TileCal cables are the same as LAr, 256
cables occupy 57,600mm.
Maximum cable bulk is 138,600mm.
Three 300mm diameter holes offer 70,000mm each.
Naive total is 210,000mm
. OK!
Deduct space for last 20 connectors, gives 40,000mm each.
Pessimistic hole space is 120,000mm
. TOO SMALL!?
Reserve space for only last 10 connectors.
Realistic(?) available hole space is 165,000mm. ADEQUATE.